Filter Results By:

Products

Applications

Manufacturers

Showing results: 2176 - 2190 of 2632 items found.

  • PXI 64x4 Matrix Module, 2-Pole, 2A, 60W

    40-583-001 - Pickering Interfaces Ltd.

    The 40-583 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 64x4 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.

  • PXI 16x16 Matrix Module, 2-Pole, 2A, 60W

    40-582-001 - Pickering Interfaces Ltd.

    The 40-582 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 16x16 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 78 pin D-Type connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.

  • PXI 32x8 Matrix Module, 2-Pole, 2A, 60W

    40-580-001 - Pickering Interfaces Ltd.

    The 40-580 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 32x8 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.

  • Extender Cards

    PCIextend 174 - Sycard Technology

    The PCIextend 174 extender card is a debug tool for 32-bit PCI designs. Designed as both an extender and debug tool, the PCIextend 174 supports both manufacturing and engineering needs. As an extender card the PCIextend extends a PCI card 2.5" above the host computer. Jumper blocks on all power supplies allow for current consumption or voltage margin testing. Multiple power status LEDs indicate 3.3V, 5V, +12V, -12V, VIO and VAUX.

  • Multimeter Test Probes

    Parrot Invent

    Multimeter Test Probes, Voltmeter  test leads,with the Parrot™ Clip Invention provide precise,  HQ, accurate, reliable contacts and connections. Parrot™ Clips with HQ leads and banana plugs or other connectors are the best solution for DDM, analog multimeter for high voltage measurements as well as for high current measurements. Measurements with multimeter test probes require both:  Hands-on  direct point contact and grip on, Hands free removable connection.

  • Load Cells

    VPG Transducers

    The heart of each weighing system is a load cell. Load cells are mechanical components which act as force sensors by employing strain gages to provide an electrical output proportional to the applied force. Typically the electrical output is either analog (voltage or current) or digital. Load cells have specific mechanical packaging and sensing orientation to fit into electronic scales, and testing and monitoring systems. Load cells can be used for tension, compression, and/or shear measurement.

  • Massively Parallel Parametric Test System

    P9001A - Keysight Technologies

    The highest throughput parallel parametric test solution. 100-pin parallel measurement capability and faster single parameter measurement than Keysight 4080. Good data correlation with Keysight 4080. New per-pin parametric test unit module with all basic measurement function (voltage, current, capacitance, pulse, frequency). Easy development of parallel test plan. Easy migration from 4080 environment. Proven in 1st-tier logic foundries and memory companies.

  • 20V/30A/300W DC Programmable Electronic Load

    TOB-IT8512 - Xiamen Tob New Energy Technology Co., Ltd

    IT8512 120V/30A/300W DC Programmable Electronic Load for Battery and Power Supply TestHigh performance and affordable single channel DC electronic load. TOB-IT8512 DC electronic loads provide you with the flexibility to test a wide range of applications from power supply, charger to battery. The high resolution voltage(1mV), current(0.1mA) measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.

  • Digital Panel Meter

    DPM - Bee Instruments

    Digital panel meters are digital displays intended to be mounted in a panel, such as a control panel. They typically read some type of input, be it a voltage, current, or resistance, and display its value digitally. Often this input is a measurement from a sensor which is converted and displayed as a temperature, pressure, or other system variable. These meters may also act as simple controllers which trip a switch or perform a simple function when the reading reaches a preset measurement.

  • Parasitic Drain Tester

    64970 - Lisle Corp.

    Replaceable in-line fuses protect both the meter and tester in the event a high current source on the vehicle is left on. The multimeter is bypassed with the switch during connection in case of a power surge. The tester and meter can remain connected until other computer systems shut down, isolating the drain. As a convenience, stacking banana connectors are used on the tester. This allows voltage to be measured on various locations on the vehicle during the drain test, using standard test leads.

  • Pulsed IV

    AURIGA 4850 - Focus Microwaves

    Auriga’s 4th generation pulsed IV/RF characterization system delivers unparalleled performance, capturing measurements with incredible speed and accuracy. Pulsed IV (current-voltage) measurements have emerged as the preferred method of capturing current-voltage characteristics of active devices such as field effect (FETs) and bipolar junction (BJTs) transistors. With the growing popularity of higher-power devices, like GaN HEMTs, LDMOS, SiC, and graphene, current and voltage requirements are constantly being pushed higher and higher.

  • Pulsed IV

    AURIGA 4850 - Mesuro Ltd

    Auriga’s 4th generation pulsed IV/RF characterization system delivers unparalleled performance, capturing measurements with incredible speed and accuracy. Pulsed IV (current-voltage) measurements have emerged as the preferred method of capturing current-voltage characteristics of active devices such as field effect (FETs) and bipolar junction (BJTs) transistors. With the growing popularity of higher-power devices, like GaN HEMTs, LDMOS, SiC, and graphene, current and voltage requirements are constantly being pushed higher and higher.

  • Solar Array Simulator DC Power Supply

    62000H-S - Chroma Systems Solutions, Inc.

    Solar Array Simulator DC Power Supplies by Chroma provide programmable simulation of Voc (open circuit voltage) up to 1800V and Isc (short circuit current) up to 30A. The 62000S-H series provides an industry leading power density in a small 3U high package. The Solar Array Simulator is highly stable and has a fast transient response design, which are both advantages to MPPT performance evaluation on PV inverter devices.

  • Electronic Transformer Test System

    UI2000-ET - Lisun Electronics Inc.

    • Input characteristics analysis 1) Measure Vrms (10-300V) Lrms (0.04-4A) W, PF, Hz, total harmonic and 0-50 component of harmonic 2) Accuracy: ± (0.4%reading + 0.1%range + 1digit) • Output characteristics analysis 1) Measure lamp voltage (1-60V) lamp current (03-20A) lamp power, crest factor and oscillatory frequency 2) Accuracy: Class 2 • It can print without compute, and provide the communication port for PC

  • Hipot Tester

    95X - Xitron Technologies Inc.

    Vitrek built the 95X Series from the ground up with DSP technology – to bring you the safest, fastest, most capable, feature rich hipot testers available. The 95X Series combines high output power, with a wide range of AC & DC voltage outputs and extremely low leakage current measurement. Then we added a 4-wire milli-ohmmeter with dynamic range up to 100K ohms and an overlapping Tera-ohm class Insulation Resistance function.

Get Help